CE marking

FCBA, as a notified body under the Construction Products Regulation (CPR), is responsible for assessing the conformity of products according to Regulation n°305/2011 which provides for the CE marking of construction products.

The FCBA Technological Institute can act as :

  • certification body for products subject to the system of assessment and verification of constancy of performance 1
  • Certification body for factory production control for products subject to the assessment and verification of constancy of performance system 2+.
  • as a testing laboratory for products subject to the system of assessment and verification of constancy of performance 3
FicheInformationsDocument to download
CE marking Finger-jointed timber for structural use

Family: Wooden structures and industrialised frameworks

Published standards/draft standards/working documents : EN 15497
Finger-joints in structural timber – Performance requirements and minimum manufacturing requirements

Intended uses : Buildings and bridges

CE marking attestation level : 1

Publication NF EN standards: –
CE marking possible : –
CE marking mandatory : –

List of valid certificates
CE marking Structural timber of rectangular cross-section

Family : Wooden structures and industrialised frameworks

Published standards/Draft standards/Working documents : Pr EN 14081
Structural timber of rectangular cross-section – Part I: Requirements

Intended uses : Buildings and bridges

Reaction to fire : Euroclass fire

CE mark certification level : 2+.

EN standards publication : May 2006

CE marking possible : July 2006

Mandatory CE marking : August 2007 (OJEC postponement = 1 January 2012)

List of holders CE marking Structural timber Rectangular section

CE marking Glued laminated timber

Family : Wooden structures and industrialised frameworks

Published standards/Draft standards/Working documents : EN 14080
Structural timber – Glued laminated timber products – Requirements

Intended uses : Buildings and bridges

CE marking attestation level : 1

EN standards publication: December 2005

CE marking possible: July 2006

Mandatory CE marking: April 2007 (OJEC postponement: 1 January 2011)

 
CE marking Cross-laminated timber

Family : Wooden structures and industrialised frameworks

Published Standards/Draft Standards/Working Papers : EAD 130005-00-0304

Intended use : Buildings

CE marking attestation level : 1

List of valid certificates
CE marking Prefabricated structural elements using pressed metal plate connectors

Family : Wooden structures and industrialised frameworks

Published standards/Draft standards/Working documents : Pr EN 14250
Timber structures – Product requirements for prefabricated trusses using connectors

Intended uses : Buildings and bridges

CE mark certification level : 2+.

EN standards publication : June 2005

CE marking possible : 27 January 2006

Mandatory CE marking : 1 January 2007 (Report OJEC: 30/09/2010)

List of valid certificates
CE marking Exterior fire resistant windows

Family : Doors, windows and closures

Published standards/Draft standards/Working documents NF EN 14351-1 + A2 : 2016 Windows and external pedestrian door units + NF EN 16034 : 2015 Pedestrian door units, doors and windows – Fire resistance and/or smoke proofing characteristics

Intended use : Fire/smoke compartments

Reaction to fire : /

CE marking attestation level : 1

Publication of EN standards : September 2016 and September 2015

CE marking possible : September 2016

Mandatory CE marking : September 2019

List of valid certificates
CE marking KERTO – RIPA

Family : Wooden structures

Published standards/Draft standards/Working documents : ETAG 019

Intended use : Buildings

Reaction to fire : /

CE marking attestation level : 1

Publication EN standards : /

Possible CE marking : NOVEMBER 2004

Mandatory CE marking : /

List of valid certificates
CE marking of timber frame house kits

Family : Timber Frame Construction

Published Standards/Draft Standards/Working Documents : ETAG 007
Timber frame house kits

Intended use : Residential buildings

CE marking attestation level : 1

EN standards publication : ETAG published on 6 September 2002

CE marking possible : 19 September 2002

Mandatory CE marking : 25 May 2004

List of valid certificates
CE marking of interior panelling and wood cladding

Family : Floor, wall and ceiling coverings

Published standards/Draft standards/Working documents : PR EN 14915
Solid wood panelling and cladding – Characteristics, conformity assessment and marking

Intended use : Floor, wall and ceiling coverings

CE marking attestation level : 3 and 4

Publication EN Standards : May 2006

CE marking possible : 20 July 2007

Mandatory CE marking : 2 June 2008 (OJEC postponement: 31/12/2009)

List of CE markings for wood panelling and cladding
CE marking Wood-based panels

Products : Uncoated, coated and veneered or finished wood-based panels

Published standards/Draft standards/Working documents : EN 13986 Wood-based panels for construction.
Characteristics, conformity assessment and marking

Intended use : structural or non-structural, interior or exterior

Reaction to fire : Euroclass fire

CE marking certification levels :
1 and 2+ (structural use)
1, 3 and 4 (non-structural use)U

Publication EN Standard : 1 October 2002

CE marking possible : 25 April 2003

Mandatory CE marking : 1 April 2004

 
CE marking of cement-bound particleboards

Text to come

CE Marking Suspended ceilings

Family : Wall, floor and ceiling coverings

Published standards/Draft standards/working documents : EN 13964
Suspended ceilings – Requirements and test methods

Intended uses : Common uses

CE Marking certification level : 1, 3 and 4

Publication EN Standards : September 2004

CE marking possible : 1 October 2005

Mandatory CE marking : 10 October 2006

CE marking External doors without fire resistance characteristics

Family : Doors, windows and closures

Published standards : EN 14351-1:2006+A2:2016
External pedestrian windows and doors without fire resistance characteristics

Intended use : Common uses, emergency exits

CE marking attestation level : 1

Publication of EN standards : mid 2006

CE marking possible : 1 February 2007

Mandatory CE marking : 1 February 2009 (Report OJEC: 01/02/2010)

CE marking Wooden poles for overhead lines

Family : Posts

Published standards/Draft standards/Working documents : Pr EN 14229
Wooden poles for overhead lines – Requirements

Intended use : Overhead lines for transmission

CE mark certification level : 2+.

Publication EN standards :

CE marking possible :

Mandatory CE marking :

CE Marking Lightweight wood-based composite beams and columns

Family : Wooden structures and industrialised frameworks

Published standards/Draft standards/Working documents : ETAG 011
Lightweight composite wood-based beams and columns

Intended use : Buildings

CE marking attestation level : 1

EN standards publication : ETAG published on 6 September 2002

CE marking possible : September 2002

Mandatory CE marking : 15 October 2004

CE marking for decorative wall coverings – rolls and panels 
CE marking Laminate flooring

Family : Flooring

Published standards/Draft standards/Working documents : NF EN 14041
Resilient textile and laminate flooring

Intended use : Flooring

CE marking certification level : 1, 3 and 4

EN standards publication : 5 March 2005

CE marking possible : 8 August 2005

Mandatory CE marking : 1 June 2006